    Boiler technical specification

    Technical description

    The boilers are suitable for family houses, apartments, smaller facilities central heating and hot water, gravity or pump heating system, where the static pressure is less than 2 bar.

    The fuel used to log wood, briquette, charcoal. The coke burning equipment must not be used!

    The boiler is made of insulating housing (optional), 2 cm insulation.

    2. Structural elements:

    2.1. boiler body

    The heat exchanger of the boiler body of 5 mm, an external water jacket 3 mm thick steel plate bent, welded. The combustion chamber, the entire surface layer of water surrounded.

    The boiler body is 100 mm tall legs, so that the floor under the boiler is easy to clean. At the beginning of the boiler door is installed in three pieces, which provide easy loading and the fuel ignited in a good cleaning and the removal of waste. The boiler water tap for filling and emptying location is provided.

    2.2. case

    The boiler body is insulated as an option, it has a casing which these elements individually, the basic version does not include the thermal insulation.

    2.3. Grate

    The boiler regardless of type, 9 1 "water pipe is welded.

    2.4. boiler doors

    The boiler door is made of steel plate 3 is equipped with a handle for easy opening and closing. The upper door to clean the boiler heat exchangers to serve. The firebox door (center) is located in the secondary air control dial secondary combustion air feeding, opening the door to this happening the fuel is supplied. the inside of the doors are fitted with heat shields, smoke-free closure sealing cord provides asbestos in the inner contour of the tömítéstartón.

    2.5. cover controller

    The basic version is equipped with a manually controlled doors. The insulated version, the controller automatically regulate the supply of the boiler primary air, making the temperature of the water supply near the regulator set temperature value is maintained. The controller of the boiler No. 10. It must be installed and 3 "connection point. No. 4 chain. hamuzó door damper A to link A and B shown below. The default setting of the air regulator valve (Figure B) must be carried out on the boiler is cold, so that the regulator is set 60-80?C.

    3 exhaust pipe

    The boiler can only be connected to a standard, tested and properly sized chimney.

    Minimum size of a Chimney
    BOILER type: ULRICH Prescribed minimum chimney cross section Useful chimney height*:
    U18 Ø150 mm 6m
    U23 Ø160 mm 6m
    U28 Ø180 mm  6m
    U38

    Ø180 mm

     6m
    U48

    Ø200 mm

     6m
    U58

    Ø200 mm

    7m
    U78

     Ø220 mm

    7m
    U98

    Ø250 mm

    8m

    * The chimney useful height of the chimney to the top of the wiring connections as appropriate.

    The boiler is only a standard sheet steel flue elbow can be used seamlessly fitted together and properly secured.

    4. Maintenance

    The equipment bag components, flue pipe and rostélycső other than regular cleaning maintenance. (As required, but at least once a week).