Thermal run-off valve

    Honeywell TS130-3/4A

    Opening temperature 95 ° C
    Brass housing, bonnet and immersion sensor pods, copper temperature sensor, high temperature resistant elastomer seals
    Max. Heating system capacity 93 kW (80,000 kcal / h)
    Mass flow rate of 2000 kg / h of water medium minimum 1.0 bar pressure
    Hose with double capillary tube sensor versions is 1/2 " 1.3 and 4.0M
    Connector size 3/4 "

    It is available on market!

    The thermal overflow valve to the boiler opens overheating. The assembly consists of a spring-loaded valve and a bellows operated temperature sensor. As soon as the boiler water temperature reaches 95 ° C, the force exerted by the bellows overcomes the spring force and opens the valve.

    The thermal drain valve is not supplied with safety features.

    Safety items

    The overheating protection system consists of a thermal valve and it regulates the safety elements (heat exchanger). The heating and water. In case of the boiler overheating of the thermal valve opens and the power of cold water passing through the security element takes the excess energy (heat from) and goes into the sewer.

    Automatic draft regulator

    Honeywell FR124-3/4A

    • vertically and horizontally built
    • Scale can be set according to the two modes of installation
    • 30-90 ° C adjustment range
    • Medium temperature of 115 ° C 3/4 "connections
    • high quality synthetic housing and adjusting wheel
    • Durable brass sensor housing
    • 1m galvanized steel chain and lever 120mm
    • easy to install and put into operation

    The draft regulator of the boiler combustion chamber regulates oxygen supply air in the furnace by varying the amount of. It opens the vent unit based on sensed by the integrated temperature sensor temperature or close the lever and chain of intermediation. Thus the intensity of the combustion process can be controlled heated water temperature.